Updating sms_def.mof sccm




















Click on the Import button. Notice that the two classes are now imported and click OK. Lastly, wait for clients to start reporting inventory. This will take up to twice the usual hardware inventory cycle before the newly inventoried regkeys will show up.

Resources The namespace for the resource that contains the displayed action name strings. The ActionUI class qualifier defines the location of the assembly and classes that are used by an action.

Control The action control displayed in the task sequence editor. It hosts the option control page. Option control The page used to manage action options, in the task sequence editor. Multiple control tabs can be implemented by including more control class names separated by commas. For example:. The VariableName qualifier is used to override the default variable name for a property.

A class property can be defined as a task sequence variable by adding the VariableName class qualifier. In the example above, the property MessageTimeout is an action variable with the name RebootTimeout. If the VariablePrefix class qualifier is used, the variables are prefixed with the class qualifier value. WMI is most often associated with hardware and most of the default information stored in WMI is hardware related, but not all of it.

Definitely a potential cause for confusion also. The main thing to know is that MOF files define classes of information, similar to classes in object-oriented programming. It does this by creating classes in this namespace that are nearly identical in definition to the class that holds or provides the real data; a. ConfigMgr matches up the names of the reporting classes to the names of data classes and then sucks out the data from the data classes.

That change will go out during the next policy interval and the clients will report the info during their next hardware inventory cycle. The PowerShell script will create the. The highlighted two attributes above are required in our example. You can create more attributes to suit your specific requirements, but if you do, make sure the same Class and Attributes are created on the server side as well. This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below.

To review, open the file in an editor that reveals hidden Unicode characters. Please see variable section. Trim spaces from the beginning and end of a string. Let's remove it! Make sure you check the language you use, since if you use some other base language than English the returned value are in that language. Modify the script to language in use. This PowerShell needs to be run on the client machine, so you can either make it run time to time on the machine with SCCM or you can set up a Task Schedule on the client machine to run the script.

NOTE All of the above results and screens shots are from my lab environment setup in a simple ConfigMgr v configuration. It is recommended that you perform these steps in a test environment before implementing in a production environment.

Hi Nicklas. Thanks for the above. If I run the netsh commands individually it give me the provider and ICCid. If you are able to assist it would be greatly appreciated Thanks Lee.

Like Like. Is the output language English or something else? Hi Nicklas, I have a question. I follow the tutorial and I noticed the script is not populating the fields on nthe. Hi Joe, I experienced the same issue. Substring Thank you for this! I did have to change one line to make it work for me. Thanks for sharing superb intomrafions. Your web site is so cool.



0コメント

  • 1000 / 1000